Gateway Administrator Guide
Version 5.1 | Published June 04, 2018 ©
Pilot and Trio Gateway Configuration
All content control applications use the same settings to connect to the database.
To access these settings use the following menu options:
-
Viz Pilot: from the main menu select Tools > External Interfaces, and the Viz Pilot Database and MOS tabs.
-
Viz Trio: from the main menu select Config > Connectivity > MOS
Gateway Configuration Pilot
Gateway Configuration Trio
Database Settings
For Viz Pilot and Viz Trio these settings are available under the VCP Database tab.
-
Connection string- Sets the connection to the database.
Note:
Use the following string format: user-name/password@database.
-
Schema- Shows the name of the Oracle schema.
Note:
The Schema name is case-sensitive, typically given in uppercase.
Gateway Connection
For Viz Pilot and Viz Trio, these buttons are available under the MOS tab.
-
Start - Starts a connection to Gateway server.
-
Stop - Close a connection to Gateway server.
-
Restart - Restarts a connection to Gateway server.
Gateway Connection Configuration
For Viz Pilot and Viz Trio, these settings are available under the MOS tab.
-
Automatic reconnect - Starts the Gateway connection automatically when starting or resetting the Media Sequencer.
-
Reconnect interval (sec) - Specifies the number of seconds that the Media Sequencer should wait, when the connection is lost, before trying to reconnect to Gateway.
-
Gateway Host - Shows the IP address of the Gateway host.
-
Gateway Port - Shows the port number on the Gateway host.
Note:
MOS ID and NCS ID should be left empty for Gateway version 2.0 or newer.
-
Send item stat - Sends feedback to the NCS via MOS, for example information about the transfer status of elements.