Explicit Usage of the Second SFP Pair on Matrox X.mio5 Q25
If the total bandwidth of all connections exceeds the available bandwidth or if an input or output needs to be moved explicitly to the second SFP pair, the following applies:
Connectors on the second SFP pair start at the values listed below:
-
Video connectors on SFP C start at 17.
-
Audio connectors on SFP C start at 129.
-
Ancillary data connectors on SFP C start at 33.
Information: For inputs this happens automatically during configuration based on the nominal bit rate of the selected resolution.
Examples
Example 1
Single Channel setup with ten 1080p inputs, input configuration:
-
Input channel 1 - 8 mapped to IP input 1 - 8.
-
Input channel 9, 10 mapped to IP input 17, 18.
Example 2
Dual Channel setup in UHD with fill/key, output configuration:
-
Viz Engine 1 program output mapped to IP output 1, IP output 2 is used by the key.
-
Viz Engine 2 program output mapped to IP output 17, IP output 18 is used by the key.